BHGPS - D.P. 149 CHEMICAL RES. EPOXY PR BA
- MSDS: BHGPS
- Manufacturer: PRATT AND LAMBERT
- Product Name: D.P. 149 CHEMICAL RES. EPOXY PR BA
- National Stock Number: 8010-00F009545
Product Identification
Product ID:D.P. 149 CHEMICAL RES. EPOXY PR BA
MSDS Date:04/10/1989
FSC:8010
NIIN:00F009545
MSDS Number: BHGPS
Responsible Party
Emergency Phone: (803) 775-6351
Info Phone: (803) 775-6351
Preparer: RON SHARPE
Cage: PRATT
Contractor
Telephone: 216-566-2902
Cage: 61196
Ingredients
3.37 LB/GAL SOLIDS
RTECS: 9999999VO
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.1 MG/M3 RDUST;9293
TALC (CONTAINING NO ASBESTOS)
CAS: 14807-96-6
RTECS: WW2710000
OSHA PEL 2 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST; 9192
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 5 - 10%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYL ISOBUTYL KETONE (SARA III)
CAS: 108-10-1
RTECS: SA9275000
Fraction By Weight: 10%
OSHA PEL 100 PPM/75 STEL
ACGIH TLV: 50 PPM/75 STEL; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ETHYL BENZENE (SARA III)
CAS: 100-41-4
RTECS: DA0700000
Fraction By Weight: <5%
OSHA PEL 100 PPM/125 STEL
ACGIH TLV: 100 PPM/125STEL 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGESTION: ASPIRATION OF MATERIAL INTO
LUNG MAY CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL. CAN CAUSE
GASTROINTESTINAL IRRITATION/NAUSEA/VOMITING. INHALATION:
NOSE/THROAT IRRITATION, CNS DEPRESSION , HEADACHES, DIZZINESS,
NAUSEA/CONFUSION. EYE/SKIN: DEFATTING & IRRITATION. MAY CAUSE
INJURY TO THE LIVER/KIDNEYS/BLOOD.
Explanation of Carcinogenicity:THE IARC FOR RESEARCH ON CANCER
CONSIDERS CRYSTALLINE SILICA TO HAVE LIMITED EVIDENCE OF
CARCINOGENICITY IN HUMANS.
Effects of Overexposure:REPEATED EXPOSURE TO CRYSTALLINE SILICA MAY
CAUSE PNEUMOCONIOSIS, A PROGRESSIVELY DISABLING LUNG DISEASE.
INHALATION: PROLONGED/REPEATED OVEREXPOSURE TO SOLVENTS W/PERMANENT
BRAIN & NERVOUS SYSTEM DAM AGE. INTENTIONAL MISUSE BY
DELIBERATELYCONCENTRATING/INHALING THE CONTENTS MAY BE HARMFUL OR
FATAL.
Medical Cond Aggravated by Exposure:PREXISTING RESPIRATORY CONDITIONS,
DEFATTING
First Aid
First Aid:INGESTION: IF SWALLOWED, DON'T INDUCE VOMITING. CALL
PHYSICIAN. INHALATION: REMOVE TO FRESH AIR. IF BREATHING HAS
STOPPED, GIVE ARTIFICIAL RESPIRATION. GET MED ATTN. EYE: FLUSH
W/LARGE AMTS OF WATER, LIFTING UPPER/LOWER LIDS OCCASIONALLY.
CONTINUE FOR AT LEAST 15 MINS. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH AFFECTED AREA W/SOAP & WATER.
Fire Fighting
Flash Point:59F
Extinguishing Media:USE NFPA CLASS B FIRE EXTINGUISHERS CO2, DRY
CHEMICAL, ALCOHOL FOAM. POLYMER FOAM IS PREFERRED FOR LARGE FIRES.
Fire Fighting Procedures:WEAR SCBA. WATER MAY BE INEFFECTIVE, BUT MAY
BE USED TO COOL EXPOSED CONTAINERS TO PREVENT PRESSURE
BUILD-UP/POSSIBLE AUTO-IGNITION/EXPLOSION/HEAT.
Unusual Fire/Explosion Hazard:DURING EMERGENCY CONDITIONS, OVEREXPOSURE
TO DECOMPOSITION PRODUCTS MAY CAUSE A HEALTH HAZARD.
WARNING-FLAMMABLE. IF WATER IS USE, FOG NOZZLES ARE PREFERABLE.
Accidental Release
Spill Release Procedures:KEEP SPECTATORS AWAY. ELIMINATE ALL IGNITION
SOURCES, FLAMES, HOT SURFACES, SPARKS. DIKE/CONTAIN SPILL W/INERT
MATERIAL (SAND/EARTH). TRANSFER LIQUIDS TO COVERED METAL CONTAINERS
FOR RECOVERY OR DISPO SAL, OR REMOVE W/INERT ABSORBENT.
Handling
Handling and Storage Precautions:DON'T STORE >95F. STORE LARGE QTYS IN
COMPLIANCE W/OSHA. DON'T TAKE INTERNALLY. CLOSE CONTAINER AFTER
EACH USE. DON'T BREATHE SANDING DUST.
Other Precautions:EMPTY CONTAINERS MUST BE NOT WASHIED/RE-USED FOR ANY
PURPOSE. CONTAINERS SHOULD BE GROUNDED/BONDED TO THE RECEIVING
CONTAINERS. DON'T WELD, BRAZE OR CUT ON EMPTY CONTAINER. NEVER USE
PRESSURE TO EMPTY . DRUM IS NOT A PRESSURE VESSEL.
Exposure Controls
Respiratory Protection:IN CONFINED AREAS USE NIOSH/MSHA APPROVED AIR
SUPPLIED RESPIRATOR. IF TLV ARE EXCEEDED USE A PROPERLY FITTED
NIOSH/MSHA APPROVED RESPIRATOR W/AN APPROPRIATE PROTECTION FACTOR.
Ventilation:PROVIDE LOCAL EXHAUST/MECHANICAL VENTILATION TO KEEP
Eye Protection:SFETY SPECTACLES
Other Protective Equipment:NOT LIKELY TO BE NEEDED
Work Hygienic Practices:REMOVE CONTAMINATED CLOTHING.
Supplemental Safety and Health
WT/GAL: 13.0 LBS. THIS PRODUCT, IF DISCARDED DIRECTLY WOULD BE
CLASSIFIED A HAZARDOUS WASTE BASED ON ITS IGNITABILITY
CHARACTERISTIC, I.E. HAS A FLASH POINT OF 140F., OR LESS. THE
PROPER RCRA CLASSIFI CIATION WOULD BE D001.
Chemical Properties
Boiling Pt:B.P. Text:182-289F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NEGLIGIBLE
Percent Volatiles by Volume:32%
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, ALKALINE MATERIALS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT & SOURCES OF
IGNITION.
Hazardous Decomposition Products:SMOKE, CO & CO2
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT, SPARKS, FLAME &
HOT SURFACES.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE W/FEDERAL, STATE & LOCAL
LAWS. INCINERATE ONLY IN EPA PERMITTED FACILITY. DON'T INCINERATE
CLOSED CONTAINERS. CONTAMINATED ABSORBANT MAY BE DISPOSED IN A
HAZARDOUS WASTE LANDFILL .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.